BUILDING PLAN MANAGEMENT SYSTEM
By Urban Development Department
\
Important Notice: We are going to conduct BPMS application training every Wednesday 11am to 12pm. Click on the link:-
https://shorturl.at/hGZ37
Proposal Status for Revised Building Permission
Proposal No
:
6393
Application No
:
RRPRGD202100016
Owner Name
:
Sandip Dilipbhai Bagul
Additional Owner List
:
View
×
Additional Owner List
Sr No
Name
Address
Mobile No
Email
No result Found
Proposal Date
:
03/06/2021
Proposal Code
:
RPRGD-21-01354
Proposal Type
:
Mixed
Proposal Plot Area
:
209.32
TDR Zone
:
A
Site Area
:
Arable Land Near Akshee Highway 6 / 6.1
Existing Building Permission Details
:
View
Office Type:
Multiple Flow:
Multiple Site Visit Status:
Site Details
Site Address
:
Panvel
Site Location
:
13
Survey Number
:
150
Plot Number
:
1
Premium FSI
:
2.000
Plot Area
:
209.32
Building and Floor Details
Existing Building Permission Details
Building Type :
MIXED
Building Category :
Mixed
Sub Category :
Mixed
Total Built Up Area :
602.13 Sq. mt.
No.of Tenements :
0
No. of Levels :
7
No. of Buildings :
1
Basement Height(m) :
0.00
Plinth Level(m) :
0.45
Residential Built Up Area :
587.61 Sq. mt.
Commercial Built Up Area :
14.52 Sq. mt.
Industrial Built Up Area :
0.00 Sq. mt.
Educational Buildup Area :
0.00
Institutional Buildup Area :
0.00
Building Height :
21.60
Plinth Intimation Taken :
Yes
Part Occupancy Taken :
No
Floor Details
Floor Name
Floor Height(m)
Bottom Level
Top Level
Floor Area
Floor Use
Parking Floor
Ground Floor
Stilt Floor
Floor Height(Below Ground Level(Meter))
Basement Floor
Re-Creation Floor
Service Floor
Podium Floor
Terrace Floor
Step Margin
Specify Floors With Identical Plan And BUA Polyline
GF
3.15
0.45
3.60
0.00
Commercial
No
Yes
Yes
0.00
0.00
Commercial
No
No
No
0.00
0
FIRST TO SIXTH
3.00
3.60
6.60
587.61
Residential
No
No
Yes
0.00
0.00
Residential
No
No
No
0.00
0
FIRST TO SIXTH
3.00
6.60
9.60
587.61
Residential
No
No
Yes
0.00
0.00
Residential
No
No
No
0.00
0
FIRST TO SIXTH
3.00
9.60
12.60
587.61
Residential
No
No
Yes
0.00
0.00
Residential
No
No
No
0.00
0
FIRST TO SIXTH
3.00
12.60
15.60
587.61
Residential
No
No
Yes
0.00
0.00
Residential
No
No
No
0.00
0
FIRST TO SIXTH
3.00
15.60
18.60
587.61
Residential
No
No
Yes
0.00
0.00
Residential
No
No
No
0.00
0
FIRST TO SIXTH
3.00
18.60
21.60
587.61
Residential
No
No
Yes
0.00
0.00
Residential
No
No
No
0.00
0
Revised Building Permission Details
Building Type :
MIXED
Building Category :
Mixed
Sub Category :
Mixed
Total Built Up Area :
634.4 Sq. mt.
No.of Tenements :
0
No. of Levels :
7
No. of Buildings :
1
Basement Height(m) :
0.00
Plinth Level(m) :
0.45
Residential Built Up Area :
619.87 Sq. mt.
Commercial Built Up Area :
14.53 Sq. mt.
Industrial Built Up Area :
0.00 Sq. mt.
Educational Buildup Area :
0.00
Institutional Buildup Area :
0.00
Building Height :
21.60
Plinth Intimation Taken :
No
Part Occupancy Taken :
No
Floor Details
Floor Name
Floor Height(m)
Bottom Level
Top Level
Floor Area
Floor Use
Parking Floor
Ground Floor
Stilt Floor
Floor Height(Below Ground Level(Meter))
Basement Floor
Re-Creation Floor
Service Floor
Podium Floor
Terrace Floor
Step Margin
Specify Floors With Identical Plan And BUA Polyline
GF
3.15
0.45
3.60
32.26
Commercial
No
Yes
Yes
0.00
0.00
Commercial
No
No
No
0.00
0
FIRST TO SIXTH
3.00
3.60
6.60
97.94
Residential
No
No
Yes
0.00
0.00
Residential
No
No
No
0.00
0
FIRST TO SIXTH
3.00
6.60
9.60
97.94
Residential
No
No
Yes
0.00
0.00
Residential
No
No
No
0.00
0
FIRST TO SIXTH
3.00
9.60
12.60
97.94
Residential
No
No
Yes
0.00
0.00
Residential
No
No
No
0.00
0
FIRST TO SIXTH
3.00
12.60
15.60
97.94
Residential
No
No
Yes
0.00
0.00
Residential
No
No
No
0.00
0
FIRST TO SIXTH
3.00
15.60
18.60
97.94
Residential
No
No
Yes
0.00
0.00
Residential
No
No
No
0.00
0
FIRST TO SIXTH
3.00
18.60
21.60
97.94
Residential
No
No
Yes
0.00
0.00
Residential
No
No
No
0.00
0
Proposal Timeline Details
Done
Pending
Reject
Architect
Pending
Approved
Service Name
: Revised Building Permission
Steps No.
Authority / Applicant
Designation
Application Received Date
Application Forward/Approve Date
Duration(In Days)
Expected Completion Days
Delay(In Days)
Project Verified By Technical
Pre Approval Payment
Document Verification
Site Inspection
Post Approval Payment Verification
Post Approval Payment
concession and relaxation
Architect Digital Signature Status
Certificate Issued
Status / Action
Remark
1
sandip bagul
Architect
03/06/2021
-
1
6
0
NA
NA
NA
NA
NA
NA
NA
NA
Forwarded
-
2
Amol Shinde
Assistant Town Planner
-
09/06/2021
1
30
0
NA
NA
NA
NA
NA
NA
NA
NA
NA
Forwarded
3
Amol Shinde
Town Planner
-
08/07/2021
1
30
0
NA
NA
NA
NA
NA
NA
NA
NA
NA
Forwarded
4
Owais Momin
Town Planner
-
09/07/2021
1
30
0
NA
NA
NA
NA
NA
NA
NA
NA
NA
Approved
5
sandip bagul
Architect
09/06/2021
-
1
6
0
NA
NA
NA
NA
NA
NA
NA
Pending
-
Revised Building Permission Insepction Report Detail
Sr No.
Authority
Designation
Site Visited Date
Visit Start Time
Visit End Time
Site Inspection Report
1
Amol Shinde
Assistant Town Planner
09/06/2021
02:10 pm
04:10 pm
View pdf
Close
Top